Fluke 87 Series V Digital Multimeters: The Industrial Standard
|
|
Item Number: 87-5
Manufacturer: Fluke
Manufacturer Part No: 87-5
|
|
From the control room to the plant floor, the Fluke 80 Series family of
digital multimeters has earned its reputation as the digital multimeter
industrial technicians trust. When productivity is on the line, the Fluke 80
Series delivers the accuracy and advanced troubleshooting capabilities you need
to solve problems fast.
Use its low pass filter function to measure
voltage and frequency accurately on electrically “noisy equipment like
adjustable speed motor drives. Use the peak capture function to detect
intermittent problems and transients as fast as 250 micro seconds (µs).
And work with confidence. The Input Alert function gives you an audible
warning against wrong use of input jacks. Fluke 80 Series multimeters are
independently tested for use in CAT IV 600V/CAT III 1000V environments. They can withstand
impulses in excess of 8,000 V and reduce risks related to surges and spikes.
At Fluke, our ideas come straight from the job site. We work with users like
you to create test tools that do the job you want for as long as you need it—and
give you full value. We design and build Fluke 80 Series multimeters in the
U.S.A. The 80 series is backed by our limited lifetime warranty. And we back
them with our limited lifetime warranty so you can work smarter, faster and
safer.
The Fluke 80 Series consists of the following models:
- Fluke 83 V Industrial DMM
- Fluke 87 V True RMS Industrial DMM
-
| Specifications
|
| Voltage DC
|
| Maximum Voltage:
|
1000V
|
| Accuracy:
|
Fluke 83 V: ±(0.1%+1)
|
|
Fluke 87 V: ±(0.05%+1)
|
| Maximum Resolution:
|
Fluke 83 V: 100 µV
|
|
Fluke 87 V: 10 µV
|
|
| Voltage AC
|
| Maximum Voltage:
|
1000V
|
| Accuracy:
|
Fluke 83 V: ±(0.5%+2)
|
|
Fluke 87 V: ±(0.7%+2) True RMS
|
| AC Bandwidth
|
Fluke 83 V: 5kHz
|
|
Fluke 87 V: 20kHz*
|
|
*with low pass filter; 3db @ 1kHz
|
| Maximum Resolution:
|
0.1 mV
|
|
| Current DC
|
| Maximum Amps:
|
10A (20 A for 30 seconds maximum)
|
| Amps Accuracy:
|
Fluke 83 V: ±(0.4%+2)
|
|
Fluke 87 V: ±(0.2%+2)
|
| Maximum Resolution:
|
Fluke 83 V: 0.01 mA
|
|
Fluke 87 V: 0.01 µA
|
|
| Current AC
|
| Maximum Amps:
|
10A (20 A for 30 seconds maximum)
|
| Amps Accuracy:
|
Fluke 83 V: ±(1.2%+2)
|
|
Fluke 87 V: ±(1.0%+2) True RMS
|
| Maximum Resolution:
|
0.1 µA
|
|
| Resistance
|
| Maximum Resistance:
|
50 MΩ
|
| Accuracy:
|
Fluke 83 V: ±(0.4%+1)
|
|
Fluke 87 V: ±(0.2%+1)
|
| Maximum Resolution:
|
0.1Ω
|
|
| Capacitance
|
| Maximum Capacitance
|
9,999 µF
|
| Accuracy
|
±(1%+2)
|
| Maximum Resolution
|
0.01 nF
|
|
| Frequency
|
| Maximum Frequency
|
200 kHz
|
| Accuracy
|
±(0.005%+1)
|
| Maximum Resolution
|
0.01 Hz
|
|
| Duty Cycle
|
| Maximum Duty Cycle
|
99.9%
|
| Accuracy
|
±(0.2% per khz +0.1%)
|
| Maximum Resolution
|
0.1%
|
|
| Temperature Measurement
|
| Fluke 87 V, 87 V/E:
|
-200.0°C - 1090°C
|
|
-328.0°F - 1994.0°F
|
|
excluding probe
|
|
| 80 BK Temperature Probe
|
|
-40.0°C - 260°C
|
|
-40.0°F - 500°F, 2.2°C or 2% whichever is
greater
|
|
| Conductance
|
| Maximum Conductance
|
60.00 nS
|
| Accuracy
|
±(1.0%+10)
|
| Maximum Resolution
|
0.01 nS
|
|
| Diode
|
| Range:
|
3 V
|
| Resolution:
|
1 mV
|
| Accuracy:
|
± (2 % + 1)
|
|
| Duty Cycle Range
|
| Accuracy:
|
Within ± (0.2% per kHz + 0.1
%)
|
|
| Environmental Specifications
|
| Operating Temperature
|
|
| Storage Temperature
|
|
| Humidity (Without Condensation)
|
|
0% - 90% (0°C - 35°C)
|
|
0% - 70% (35°C - 55°C)
|
|
| Operating Altitude
|
|
| Safety Specifications
|
| Overvoltage category
|
|
EN 61010-1 to 1000 V CAT III, 600V CAT
IV
|
|
| Agency Approvals
|
|
| Mechanical & General Specifications
|
| Size
|
|
201 x 98 x 52 mm (with holster)
|
|
| Weight
|
|
| Weigh With Holster and Flex-Stand
|
|
| Display
|
| Digital:
|
6000 counts updates 4/sec.
|
|
(Model 87 also has 19,999 counts in high-resolution mode.)
|
| Analog:
|
32 segments, updates 40/sec.
|
| Frequency:
|
19,999 counts, updates 3/sec at > 10
Hz.
|
|
| Warranty
|
|
| Battery Life
|
| Alkaline:
|
~400 hours typical, without backlight
|
|
| Shock
|
|
1 Meter drop per IEC 61010-1:2001
|
|
| Vibration
|
|
Per MIL-PRF-28800 for a Class 2 instrument
|
|
|
New features for maximum productivity
- Unique function for accurate voltage and frequency measurements on
adjustable speed motor drives and other electrically noisy equipment (87V)
- Built-in thermometer conveniently allows you to take temperature readings
without having to carry a separate instrument (87V)
- Optional magnetic hanger for easy set-up and viewing while freeing your
hands for other tasks
- Large digit display with bright, two-level backlight makes the 80- Series V
significantly easier to read than older
models
|
| Feature
|
83V
|
87V
|
| True-rms ac voltage and current for accurate
measurements on non linear signals
|
|
•
|
| Selectable filter for accurate voltage and
frequency measurements on motor drives
|
|
•
|
| 0.05 % dc accuracy
|
|
•
|
| 6000 counts, 3-3/4 digits
|
•
|
•
|
| 4-1/2 digit mode for precise measurements (20,000
counts)
|
|
•
|
| Measure up to 1000 V ac and dc
|
•
|
•
|
| Measure up to 10 A, 20 A for up to 30
seconds
|
•
|
•
|
| Built in thermometer lets you carry one less tool
(TC probe included)
|
|
•
|
| Frequency to 200 kHz and % duty cycle
|
•
|
•
|
| Resistance, continuity and diode test
|
•
|
•
|
| 10,000 µF capacitance range for components and
motor caps
|
•
|
•
|
| Min/Max-Average recording with Min/Max Alert to
capture variations automatically
|
•
|
•
|
| Peak capture to record transients as fast as 250
µs
|
•
|
•
|
| Relative mode to remove test lead interference from
low ohms measurements
|
•
|
•
|
| Auto and manual ranging for maximum
flexibility
|
•
|
•
|
| Touch Hold to capture stable readings avoiding
noisy signals
|
•
|
•
|
| Large display digits and two-level bright white
backlight for increased visibility
|
•
|
•
|
| Analog bargraph for fast changing or unstable
signals
|
•
|
•
|
| Input Alert provides audible warning against wrong
use of input jacks
|
•
|
•
|
| Improved selectable sleep mode for long battery
life
|
•
|
•
|
| Access door for fast battery changes without
breaking the calibration seal
|
•
|
•
|
| "Classic" design with new removable holster with
built in test lead and probe storage
|
•
|
•
|
| Lifetime warranty
|
•
|
•
|
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA
S82.01 and EN61010-1 CAT IV 600V and CAT III, 1000 V. They can withstand
impulses in excess of 8.000 V and reduce risks related to surges and
spikes.

Correctly measure pulse-width modulated motor drive
signals
Until now, there hasn't been a
multimeter able to accurately measure adjustable speed drives. But the new Fluke
87V is designed specifically to handle these complex signals. Think of the
potential productivity you'll gain by taking the guesswork out of drive system
troubleshooting. Measurements are correct each and every time.
- Unique function for accurate measurements of noisy pulse-width modulated AC
voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not
affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare reading from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by
large drive systems
|
|
| Complex PWM drive
signals are not a problem for the Fluke 87V
|
|
| Pulse-width
modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second
pulses can cause erratic behavior in some test
equipment.
|
|
| Specifications
|
| Voltage DC
|
| Maximum Voltage:
|
1000V
|
| Accuracy:
|
Fluke 83 V: ±(0.1%+1)
|
|
|
Fluke 87 V: ±(0.05%+1)
|
| Maximum Resolution:
|
Fluke 83 V: 100 µV
|
|
|
Fluke 87 V: 10 µV
|
|
| Voltage AC
|
| Maximum Voltage:
|
1000V
|
| Accuracy:
|
Fluke 83 V: ±(0.5%+2)
|
|
|
Fluke 87 V: ±(0.7%+2) True RMS
|
| AC Bandwidth
|
Fluke 83 V: 5kHz
|
|
|
Fluke 87 V: 20kHz*
|
|
|
*with low pass filter; 3db @ 1kHz
|
| Maximum Resolution:
|
0.1 mV
|
|
| Current DC
|
| Maximum Amps:
|
10A (20 A for 30 seconds maximum)
|
| Amps Accuracy:
|
Fluke 83 V: ±(0.4%+2)
|
|
|
Fluke 87 V: ±(0.2%+2)
|
| Maximum Resolution:
|
Fluke 83 V: 0.01 mA
|
|
|
Fluke 87 V: 0.01 µA
|
|
| Current AC
|
| Maximum Amps:
|
10A (20 A for 30 seconds maximum)
|
| Amps Accuracy:
|
Fluke 83 V: ±(1.2%+2)
|
|
|
Fluke 87 V: ±(1.0%+2) True RMS
|
| Maximum Resolution:
|
0.1 µA
|
|
| Resistance
|
| Maximum Resistance:
|
50 MΩ
|
| Accuracy:
|
Fluke 83 V: ±(0.4%+1)
|
|
|
Fluke 87 V: ±(0.2%+1)
|
| Maximum Resolution:
|
0.1Ω
|
|
| Capacitance
|
| Maximum Capacitance
|
9,999 µF
|
| Accuracy
|
±(1%+2)
|
| Maximum Resolution
|
0.01 nF
|
|
| Frequency
|
| Maximum Frequency
|
200 kHz
|
| Accuracy
|
±(0.005%+1)
|
| Maximum Resolution
|
0.01 Hz
|
|
| Duty Cycle
|
| Maximum Duty Cycle
|
99.9%
|
| Accuracy
|
±(0.2% per khz +0.1%)
|
| Maximum Resolution
|
0.1%
|
|
| Temperature Measurement
|
| Fluke 87 V, 87 V/E:
|
-200.0°C - 1090°C
|
|
|
-328.0°F - 1994.0°F
|
|
|
excluding probe
|
|
| 80 BK Temperature Probe
|
|
|
-40.0°C - 260°C
|
|
|
-40.0°F - 500°F, 2.2°C or 2% whichever is
greater
|
|
| Conductance
|
| Maximum Conductance
|
60.00 nS
|
| Accuracy
|
±(1.0%+10)
|
| Maximum Resolution
|
0.01 nS
|
|
| Diode
|
| Range:
|
3 V
|
| Resolution:
|
1 mV
|
| Accuracy:
|
± (2 % + 1)
|
|
| Duty Cycle Range
|
| Accuracy:
|
Within ± (0.2% per kHz + 0.1
%)
|
|
| Environmental Specifications
|
| Operating Temperature
|
|
| Storage Temperature
|
|
| Humidity (Without Condensation)
|
|
|
0% - 90% (0°C - 35°C)
|
|
|
0% - 70% (35°C - 55°C)
|
|
| Operating Altitude
|
|
| Safety Specifications
|
| Overvoltage category
|
|
|
EN 61010-1 to 1000 V CAT III, 600V CAT
IV
|
|
| Agency Approvals
|
|
| Mechanical & General Specifications
|
| Size
|
|
|
201 x 98 x 52 mm (with holster)
|
|
| Weight
|
|
| Weigh With Holster and Flex-Stand
|
|
| Display
|
| Digital:
|
6000 counts updates 4/sec.
|
|
|
(Model 87 also has 19,999 counts in high-resolution mode.)
|
| Analog:
|
32 segments, updates 40/sec.
|
| Frequency:
|
19,999 counts, updates 3/sec at > 10
Hz.
|
|
| Warranty
|
|
| Battery Life
|
| Alkaline:
|
~400 hours typical, without backlight
|
|
| Shock
|
|
|
1 Meter drop per IEC 61010-1:2001
|
|
| Vibration
|
|
|
Per MIL-PRF-28800 for a Class 2
instrument
|
|
|
| Model Name
|
Description
|
Price List
|
Buy it
|
| Fluke 83V
|
Multimeter
Includes:
- TL75 test leads
- AC72 Alligator Clips
- Holster
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
|
|
|
|
| Fluke 87V
|
Multimeter
Includes:
- TL75 test leads
- AC72 Alligator Clips
- Holster
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
- 80BK temperature probe
|
|
|
|
| Fluke 87V/E2 Kit
|
Includes:
- 87V Multimeter
- TL224 silicone test leads
- AC220 long reach alligator clips
- TP238 test probes
- TPAK ToolPak™ Magnetic Meter Hanging Kit
- 80BK temperature probe
- C35 lightweight soft accessory case
- 9V battery (installed)
- Getting Started Manual
- CD with detailed manual
|
|
|
|
| Test Leads
|
Buy it
|
| H900
|
Test Lead Holder
|
|
|
| TL223
|
SureGrip™ Electrical Test Lead Set
|
|
|
| Pressure
|
Buy it
|
| PV350
|
Pressure Vacuum Module
|
|
|
| Test Leads Probes and Clips
|
Buy it
|
|
|
SureGrip™ Alligator Clips
|
|
|
|
|
SureGrip™ Industrial Test Lead Set
|
|
|
|
|
Deluxe Electronic Test Lead Set
|
|
|
|
|
SureGrip™ Industrial Test Lead
|
|
|
|
|
SureGrip™ Master Accessory Set
|
|
|
| 85RF
|
High Frequency Probe
|
|
|
| AC220
|
SureGrip™ Alligator Clips
|
|
|
| AC280
|
SureGrip™ Hook Clips
|
|
|
| AC283
|
SureGrip™ Pincer Clips
|
|
|
| AC87
|
Heavy Duty Bus Bar Clips
|
|
|
| AC89
|
Heavy Duty Insulation Piercing Test Clip
|
|
|
| BP980
|
Double Banana Plug Kit
|
|
|
| TL221
|
SureGrip™ Test Lead Extension Set
|
|
|
| TL222
|
SureGrip™Silicone Insulated Test Leads
|
|
|
| TL224
|
SureGrip™ Insulated Test Leads
|
|
|
| TL225
|
Stray Voltage Adapter Test Lead Kit
|
|
|
| TL26A
|
60 in. 5-Way Test Lead Set
|
|
|
| TL40
|
Retractable Tip Test Lead Set
|
|
|
| TL71
|
Test Lead Set
|
|
|
| TL75
|
Hard Point Test Lead Set
|
|
|
| TL76
|
2mm/4mm Test Lead Set
|
|
|
| TL80A
|
Basic Electronic Test Lead Set
|
|
|
| TL910
|
Electronic Test Probes
|
|
|
| TL930
|
Patch Cords (60 cm)
|
|
|
| TL932
|
Patch Cords (90 cm)
|
|
|
| TL935
|
Patch Cords (60, 90, 120 cm)
|
|
|
| TL940
|
Mini-Hook Test Leads
|
|
|
| TL950
|
Mini-Pincer Test Leads
|
|
|
| TL960
|
Micro-Hook Test Leads
|
|
|
| TL970
|
Hook and Pincer Set
|
|
|
| TLK220
|
SureGrip™ Industrial Test Lead Kit
|
|
|
| TP1
|
Slim Reach Test Probes (flat blade)
|
|
|
| TP2
|
Slim Reach Test Probes (2 mm)
|
|
|
| TP220
|
SureGrip™ Industrial Test Probes
|
|
|
| TP4
|
Slim Reach Test Probes (4 mm)
|
|
|
| TP74
|
Lantern Tip Test Probes
|
|
|
| TP80
|
Electronic Test Probes
|
|
|
| TP912
|
Replacement Tips for TL910
|
|
|
| TP920
|
Test Probe Adapter Set
|
|
|
| Cases-Holsters
|
Buy it
|
|
|
Gear Box for Meter and Accessories
|
|
|
|
|
Large Soft Case for DMMs
|
|
|
|
|
Soft Carrying Case
|
|
|
|
|
Extreme Case
|
|
|
|
|
ToolPak, Meter Hanging Kit
|
|
|
| C100
|
Universal Carrying Case
|
|
|
| C101
|
Hard Case
|
|
|
| C550
|
Tool Bag
|
|
|
| C800
|
Hard Meter and Accessory Case
|
|
|
| Fluke
MeterCleaner Wipes
|
Fluke MeterCleaner Wipes
|
|
|
| H80M
|
Protective Holster with Magnetic Hanging Strap
|
|
|
| Current-Clamps
|
Buy it
|
|
|
AC/DC Current Clamp and Carry Case Kit
|
|
|
|
|
AC Current Clamp
|
|
|
| i1010
|
AC/DC Current Clamp
|
|
|
| i200
|
AC Current Clamp
|
|
|
| i2000
flex
|
AC Current Clamp
|
|
|
| i410
|
AC/DC Current Clamp
|
|
|
| i410-KIT
|
AC/DC Current Clamp and Carry Case Kit
|
|
|
| High-Voltage-Probes
|
Buy it
|
|
|
High Voltage Probe
|
|
|
| 80K-6
|
High Voltage Probe
|
|
|
| Fiber-Optics
|
Buy it
|
| FOM
|
Fiber Optic Meter
|
|
|
| Temperature
|
Buy it
|
|
|
Thermocouple Adapter
|
|
|
|
|
Tapered Temperature Probe
|
|
|
| 80PK-11
|
Type-K Flexible Cuff Thermocouple Temperature
Probe
|
|
|
| 80PK-24
|
Air Temperature Probe
|
|
|
| 80PK-25
|
Piercing Temperature Probe
|
|
|
| 80PK-27
|
Industrial Surface Temperature Probe
|
|
|
| 80PK-8
|
Pipe Clamp Temperature Probe (Type K)
|
|
|
| Lights
|
Buy it
|
|
|
Probe Light Kit
|
|
|
| L200
|
Probe Light
|
|
|
| L215
|
SureGrip™ Kit with Probe Light and Probe Extender
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|